Direct YouTube Link: https://youtu.be/Sgtdmtl1XWw
00:47.13 Begin by removing the grill. 00:54.00 Using a 14 mm wrench, remove the retention nut for the cold control. 01:02.00 Lower the cold control and disconnect the color-coded wires. Carefully noting the terminals in which each wire is connected. 01:13.90 Remove the back panel screws to remove the cover. 01:24.00 Partially remove the sealant over the sensing tube’s entry point and gently remove the sensor. 01:33.00 Carefully unroll the new sensing tube on the new cold control. 01:42.00 Carefully route the sensing tube to avoid damage. 01:50.00 Reinstall the wires on their appropriate terminals. 02:06.00 Mount the cold control using the alignment pin in the indexing window of the bracket. 02:24.00 Insert the temperature probe through the cabinet and into the mold cavity, ensuring the probe reaches its maximum depth. 02:34.00 Route the sensing tube down the back of the unit and carefully spooling any residual amounts. 02:45.00 Reapply the sealant to putty over the opening. 02:50.86 Reinstall the units back panel.
Marine Ice Maker Icerette Model 87 The marine environment is harsh for household type appliances. Keeping that harshness in mind, Raritan developed and designed our Ice-maker so that it would withstand the vigor of any marine environment.